Type |
URE-250-240A |
Input (DC) |
Max Recommended PV Power (Wp) |
285 |
Max DC Open Circuit Voltage (Vdc) |
60 |
Max DC Input Current (Adc) |
12 |
MPPT Tracking Accuracy |
>99.5% |
MPPT Tracking Range (Vdc) |
22-55 |
Isc PV (absolute maximum) (Adc) |
14 |
Maximum Inverter Backfeed Current to the Array (Adc) |
0 |
Output (AC) |
Rated AC Output power (Wp) |
220 |
Nominal power Grid Voltage (Vac) |
240 |
Allowable Power Grid Voltage (Vac) |
211-264* |
Allowable Power Grid Frequency (Hz) |
59.3-60.5* |
THD |
<3% (at rated power) |
Power Factor (cos phi, fixed) |
>0.99% |
Rated Output Current (Aac) |
0.92 |
Current (inrush) (Peak and Duration) |
12A, 15us |
Nominal Frequency (Hz) |
60 |
Maximum Output Fault Current (Aac) |
2.2A peak |
Maximum Output Over current Protection (Aac) |
6.3 |
Max. Number of Units Per Branch (20A/15A circuit) |
13 |
System Efficiency |
Weighted Averaged Efficiency (CEC) |
95% |
Night Time Tare Loss (Wp) |
0.17 |